OWNERS MANUAL iForks
21
6.7 Error messages
ERROR MESSAGES
Display
Meaning
Out of error mode
Err01
Load cell signal is unstable
Automatic
Err02
Overload on full scale
Automatic after removing weight
Err03
Gross negative. This action is not allowed
Automatic
Err04
Out of zero range
Press any key
Err05
Sampling accuracy too low
Press any key
Err06
Input signal too high
Automatic after correcting input
Err08
Calibration out of range (negative)
Automatic
Err09
Calibration out of range (signal too low)
Automatic
Err10
Calibration count 2nd(3rd) point lower than count
1st(2nd) point
Automatic
Err14
Setpoint value 2 < setpoint value 1. This is not allowed
Automatic
Err98
Calibration point must be higher than previous one
Automatic
Err99
ErrF1
ErrF2
----
L - _
ErrCS
Action only allowed in start-up units
Problem with fork 1 (no communication)
Problem with fork 2 (no communication)
Loadcell signal negative
Forks are out of level (only legal-for-trade version)
Problem with correction sensor
Automatic
Restart indicator. Restart forks & indicator
Restart indicator. Restart forks & indicator
Lift up the forks from the ground
Put the forks into horizontal position
Contact the RAVAS Service department
DISPLAY MESSAGES
Display
Meaning
BltF1
BltF2
Successful Bluetooth link with fork 1
Successful Bluetooth link with fork 2
No error
No error
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - OWNERS MANUAL – iForks

OWNERS MANUAL – iForks 21 6.7 Error messages ERROR MESSAGES Display Meaning Out of error mode Err01 Load cell signal is unstable Automatic Er

Page 2

OWNERS MANUAL – iForks 30 6.11 User settings 2 1 3 CLR3 sec. EXIT without SAVING EXIT & SAVE Back to weigh mode Back to weigh mode e1 e2 e3 F1

Page 3

OWNERS MANUAL – iForks 31 Set the auto shut-off time indicator (delay time in minutes) Set backlight (intensity in %) 0 min = indicator always on

Page 4

OWNERS MANUAL – iForks 32 (De-) activate Com Port 2 (De-) activate Com Port 1 It is not possible to de-activate Com Port 1 for iForks forks”

Page 5

OWNERS MANUAL – iForks 33 7. Calibration 7.1 Corner calibration e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLR2 sec. ????2 1 6 3 4 5 e1 e2 e3 F1 F2

Page 6

OWNERS MANUAL – iForks 34 8 7 12 9 10 11 B ACDPut load M (100–500kg) on position A of the pallet. e1 e2 e3 F1 F2NETID CODEPTTOTALPCS KG/LBCLRe1 e2 e

Page 7

OWNERS MANUAL – iForks 35 14 13 18 15 16 17 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRABCDe1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRe1 e2 e3

Page 8

OWNERS MANUAL – iForks 36 7.2 Zero calibration 2 1 3 4 e1 e2 e3 F1 F2NETID CODEPTTOTALPCS KG/LBCLRStart up the indicator. Press the on/off key. Em

Page 9 - 6.10 KG- LB switch

OWNERS MANUAL – iForks 37 7.3 Weight calibration 2 1 6 3 4 5 e1 e2 e3 F1 F2NETID CODEPTTOTALPCS KG/LBCLRStart up the indicator. Press the on/off ke

Page 10 - 10 sec

OWNERS MANUAL – iForks 38 8 7 12 9 10 11 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRChange if needed ! e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCL

Page 11

OWNERS MANUAL – iForks 39 e1 e2 e3 F1 F214 13 18 15 16 17 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRM2e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLR

Page 12

OWNERS MANUAL – iForks 22 6.8 Net / Tare / Gross weight EXPLANATION: Net(1) + Tare(2) = Gross(3) 6.8.1 Net weighing: automatic

Page 13 - 7. Calibration

OWNERS MANUAL – iForks 40 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLR 20 19 21 1x e1 e2 e3 F1

Page 14

OWNERS MANUAL – iForks 41 2. Parameter settings Par. Function Default settings EU US Settings 01 Calibration and start-up units (and pri

Page 15

OWNERS MANUAL – iForks 42 Bluetooth connection! Enter last 6 characters of MAC-address of fork1 and 2 or cancel by pressing CLR 90 Default settings

Page 16

OWNERS MANUAL – iForks 23 5 7 8 9 The display shows the net value of the weighed load. The gross weight is displayed again. 1000e1 e2 e3 F1 F2NETID

Page 17

OWNERS MANUAL – iForks 24 3 sec. e1 e2 e3 F1 F2NETID CODEPTTOTALPCS KG/LBCLRe1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRe1 e2 e3 F1 F2NETID CODEPTTO

Page 18

OWNERS MANUAL – iForks 25 8 7 12 9 10 11 The “NET”pointer lights up When the iForks are completely unloaded, the tare value is displayed negatively

Page 19

OWNERS MANUAL – iForks 26 14 13 The gross weight is displayed again. e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRe1 e2 e3 F1 F2NETID CODEPTTOTALPCS

Page 20 - OWNERS MANUAL – iForks

OWNERS MANUAL – iForks 27 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRe1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLR6.9 Adding & reset Press t

Page 21 - 2. Parameter settings

OWNERS MANUAL – iForks 28 3 sec. e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLR3 sec. CLR 8 7 9 The subtotal can be checked by pressing the TOTA

Page 22

OWNERS MANUAL – iForks 29 6.10 KG- LB switch 2 1 e1 e2 e3 F1 F2NETID CODEPTTOTAL PCS KG/LBCLRkgKG/LB5 sec. e1 e2 e3 F1 F2NETID C

Comments to this Manuals

No comments